Difference between revisions of "SimWorld Hardware"

From Manuals
Jump to: navigation, search
(Created page with "==General information== Overhead, MIP, Gauges and MCP is supported. MIP, Pedestal, Gauges and MCP is connected with CAN bus technology. A power cable and CAN bus ‘connection...")
 
Line 1: Line 1:
 
==General information==
 
==General information==
Overhead, MIP, Gauges and MCP is supported. MIP, Pedestal, Gauges and MCP is connected with CAN bus technology. A power cable and CAN bus ‘connection’ cable will be connected to a “SimBox”. The SimBox will be connected to the primary computer.
+
All SimWorld hardware is natively suported by ProSim - no external driver necessary.
 +
 
 +
MIP, Pedestal, Gauges and MCP is connected with CAN bus technology. A power cable and CAN bus ‘connection’ cable will be connected to a “SimBox”. The SimBox will be connected to the primary computer.
 +
 
 
The IO modules will be connected automatically when the "SimWorld hardware support" is enabled in the driver page (see below). The USB should be connected as HID device without any driver installed.
 
The IO modules will be connected automatically when the "SimWorld hardware support" is enabled in the driver page (see below). The USB should be connected as HID device without any driver installed.
  
 
+
Always follow the instructions supplied with the hardware!
 
==Supported specific hardware==
 
==Supported specific hardware==
 
===FWD & AFT Overhead===
 
===FWD & AFT Overhead===
Overhead panels are connected directly with USB interface and not through "SimBox".
+
Overhead panels are connected directly with USB interface and not through "SimBox" CAN bus interface.
In ProSim737 System->Config->Configuration->Drivers enable "SimWorld hardware support"
+
 
 +
In ProSim737 System->Config->Configuration->Drivers, enable "SimWorld hardware support"
 
Restart ProSim737 Systems
 
Restart ProSim737 Systems
 
Both panels are PnP and don't require any further configuration.
 
Both panels are PnP and don't require any further configuration.
Line 13: Line 17:
 
===CDU===
 
===CDU===
 
CDU is connected through SimBox and CAN bus cable.
 
CDU is connected through SimBox and CAN bus cable.
 +
 
"SimWorld hardware support" must be enabled in ProSim737 System
 
"SimWorld hardware support" must be enabled in ProSim737 System
 
Correct role (capt/fo) must be configured in the ProSim737 CDU to match the hardware configuration
 
Correct role (capt/fo) must be configured in the ProSim737 CDU to match the hardware configuration
Line 18: Line 23:
 
===MCP/EFIS===
 
===MCP/EFIS===
 
CDU is connected through SimBox and CAN bus cable.
 
CDU is connected through SimBox and CAN bus cable.
 +
 
"SimWorld hardware support" must be enabled in ProSim737 System
 
"SimWorld hardware support" must be enabled in ProSim737 System
 
No configuration neccessary in ProSim737 MCP, but ProSim737 MCP must be running
 
No configuration neccessary in ProSim737 MCP, but ProSim737 MCP must be running
Line 23: Line 29:
 
===MIP===
 
===MIP===
 
MIP is connected through SimBox and CAN bus cable.
 
MIP is connected through SimBox and CAN bus cable.
 +
 
"SimWorld hardware support" must be enabled in ProSim737 System
 
"SimWorld hardware support" must be enabled in ProSim737 System
 
MIP is PnP and don't require any further configuration.
 
MIP is PnP and don't require any further configuration.

Revision as of 20:57, 20 March 2018

1 General information

All SimWorld hardware is natively suported by ProSim - no external driver necessary.

MIP, Pedestal, Gauges and MCP is connected with CAN bus technology. A power cable and CAN bus ‘connection’ cable will be connected to a “SimBox”. The SimBox will be connected to the primary computer.

The IO modules will be connected automatically when the "SimWorld hardware support" is enabled in the driver page (see below). The USB should be connected as HID device without any driver installed.

Always follow the instructions supplied with the hardware!

2 Supported specific hardware

2.1 FWD & AFT Overhead

Overhead panels are connected directly with USB interface and not through "SimBox" CAN bus interface.

In ProSim737 System->Config->Configuration->Drivers, enable "SimWorld hardware support" Restart ProSim737 Systems Both panels are PnP and don't require any further configuration.

2.2 CDU

CDU is connected through SimBox and CAN bus cable.

"SimWorld hardware support" must be enabled in ProSim737 System Correct role (capt/fo) must be configured in the ProSim737 CDU to match the hardware configuration

2.3 MCP/EFIS

CDU is connected through SimBox and CAN bus cable.

"SimWorld hardware support" must be enabled in ProSim737 System No configuration neccessary in ProSim737 MCP, but ProSim737 MCP must be running

2.4 MIP

MIP is connected through SimBox and CAN bus cable.

"SimWorld hardware support" must be enabled in ProSim737 System MIP is PnP and don't require any further configuration.


3 Troubleshooting

3.1 ProSim737 panel

TBA